Element Hot Water Cylinders

Our Element hot water cylinders have 28 mm inlet and outlet connections and are available in a wide variety of capacities to suit the demands of the property.

ELEMENT PRO
For installations requiring faster recovery times, the Element Pro range features an up-rated primary coil and 6 kW immersion heater. Reheat times for this range are as fast as seven minutes.

ELEMENT DIRECT
Where no external heat source is available, the Element Direct range features a 2 x 3 kW immersion heater as standard.

ELEMENT SOLAR
With an additional secondary coil, the Element Solar range is ideal for renewable energy sources, including solar panels.

Product specification

Speak to an expert
Element vertical cylinders (4.5 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC08045V
80
4.5
18
B
EUHPC15045V
150
4.5
24
B
EUHPC17545V
175
4.5
24
C
EUHPC21545V
215
4.5
35
C
EUHPC25045V
250
4.5
35
C
EUHPC30045V
300
4.5
50
C
EUHPC40045V
400
4.5
80
B
EUHPC50045V
500
4.5
100
B
Element Pro fast recovery vertical cylinders (4.5 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC17545V-FR
175
4.5
24
C
EUHPC21545V-FR
215
4.5
35
C
EUHPC25045V-FR
250
4.5
35
C
EUHPC30045V-FR
300
4.5
50
C
EUHPC40045V-FR
400
4.5
80
B
EUHPC50045V-FR
500
4.5
100
B
Element Direct vertical cylinders (4.5 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC08045V-DR
80
4.5
18
B
EUHPC15045V-DR
150
4.5
24
B
EUHPC17545V-DR
175
4.5
24
C
EUHPC21545V-DR
215
4.5
35
C
EUHPC25045V-DR
250
4.5
35
C
EUHPC30045V-DR
300
4.5
50
C
EUHPC40045V-DR
400
4.5
80
C
EUHPC50045V-DR
500
4.5
100
C
Element vertical cylinders (6 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC08060V
80
6
18
B
EUHPC15060V
150
6
24
B
EUHPC17560V
175
6
35
C
EUHPC21560V
215
6
35
C
EUHPC25060V
250
6
50
C
EUHPC30060V
300
6
50
C
EUHPC40060V
400
6
80
B
EUHPC50060V
500
6
100
B
Element Pro fast recovery vertical cylinders (6 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC17560V-FR
175
6
35
C
EUHPC21560V-FR
215
6
35
C
EUHPC25060V-FR
250
6
50
C
EUHPC30060V-FR
300
6
50
C
EUHPC40060V-FR
400
6
80
B
EUHPC50060V-FR
500
6
100
B
Element Direct vertical cylinders (6 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC08060V-DR
80
6
18
B
EUHPC15060V-DR
150
6
24
B
EUHPC17560V-DR
175
6
35
C
EUHPC21560V-DR
215
6
35
C
EUHPC25060V-DR
250
6
50
C
EUHPC30060V-DR
300
6
50
C
EUHPC40060V-DR
400
6
80
C
EUHPC50060V-DR
500
6
100
C
Element vertical cylinders – reduced height (4.5 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC30045V-RH
300
4.5
50
B
EUHPC40045V-RH
400
4.5
80
C
EUHPC50045V-RH
500
4.5
100
C
Element Pro fast recovery vertical cylinders – reduced height (4.5 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC30045V-FR-RH
300
4.5
50
B
EUHPC40045V-FR-RH
400
4.5
80
C
EUHPC50045V-FR-RH
500
4.5
100
C
Element vertical cylinders – reduced height (6 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC30060V-RH
300
6
50
B
EUHPC40060V-RH
400
6
80
C
EUHPC50060V-RH
500
6
100
C
Element Pro fast recovery vertical cylinders – reduced height (6 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC30060V-FR-RH
300
6
50
B
EUHPC40060V-FR-RH
400
6
80
C
EUHPC50060V-FR-RH
500
6
100
C
Element horizontal cylinders (4.5 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC15045H
150
4.5
24
B
EUHPC17545H
175
4.5
24
B
EUHPC21545H
215
4.5
35
C
EUHPC25045H
255
4.5
35
C
EUHPC30045H
305
4.5
50
C
EUHPC40045H
400
4.5
80
B
EUHPC50045H
500
4.5
100
B
Element horizontal cylinders (6 bar)
Model no.
Capacity (L)
Max operating pressure (bar)
Expansion vessel (L)
ERP rating
EUHPC15060H
150
6
24
B
EUHPC17560H
175
6
35
C
EUHPC21560H
215
6
35
C
EUHPC25060H
255
6
50
C
EUHPC30060H
305
6
50
C
EUHPC40060H
400
6
80
B
EUHPC50060H
500
6
100
B

Manuals

Ultra-high performance indirect hot water cylinder O&M manual.

WRAS Certificates

Hot hater cylinder WRAS approval certificate.

Brochure

A technical overview of Dutypoint hot water cylinders.

Standard technical features

28 mm connections for high flow rates
4.5 bar and 6.0 bar versions for high-pressure installations
WRAS approved for potable water
Expansion vessel and two-port motorised zone valve included
3 kW electric immersion heater in addition to the primary coil
½” hot-water secondary return as standard
High-performance insulation minimises energy loss
High-grade duplex stainless steel construction for excellent durability
22 mm or 28 mm diameter stainless steel heating coil for fast reheating times
Durable plastisol casing
Factory-fitted pressure and temperature relief valve

Approvals

Building Standards: BS 853-1-1996 & BS-12-897
Building Regulations: Part G & L

Guarantee

Internal cylinder: 25 years
Ancillary components: 1 year

Options

Additional coil for secondary heat sources, e.g. solar panels or air/ground source heat pumps
Uprated primary coil for faster recovery times (available on 175-litre and larger models)
6 kW immersion heater (standard on Pro versions)
Twin immersion heaters
1” hot-water secondary return
Non-standard sizes
Direct cylinders (immersion heater only)

Flow rate
Up to 77 litres/minute
Inlet and outlet size
28 mm
Immersion heater kW
3 kW or 6 kW
Operating pressure
4.5 bar or 6.0 bar
Relief valve pressure